CVE-2026-123634F5 Dos use-after-free
Scor CVSS
9.2
Critic
CVSS 4.0 de la f5.com
Probabilitate de exploatare (EPSS)
17.1%
Șansă de 17.1% să fie exploatată în următoarele 30 de zile, peste 97.2% dintre toate CVE-urile.
CISA KEV
Nu este în KEV
CISA nu a raportat până acum exploatări confirmate.
Descrierea oficială
This issue occurs when NGINX Plus or NGINX Open Source is configured as a proxy, the proxied server name includes variables, and a Server Side Includes (SSI) or mirror directive sends a subrequest to a location that resolves the same server name. Under these conditions, a specially crafted HTTP request may cause a use-after-free condition in a worker process. An attacker may also be able to execute code if Address Space Layout Randomization (ASLR) is disabled or the attacker can bypass ASLR.
Impact:
An attacker could leverage this vulnerability to crash the NGINX worker process, corrupt its memory, or perform remote code execution (RCE)
Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
Sursa: NVD · CNA: f5sirt@f5.com
Cum îl remediezi, pas cu pas
Verifică dacă ești afectat
Identifică toate sistemele care rulează F5 Dos, F5 Nginx Gateway Fabric, F5 Nginx Ingress Controller, F5 Nginx Instance Manager, F5 Nginx Open Source și compară versiunea lor cu versiunile afectate.
Actualizează la o versiune remediată
- Actualizează Nginx Open Source la 0.8.55, 1.30.7, 1.31.9 sau mai nou, pe ramura pe care o folosești.
- Actualizează Nginx Ingress Controller la 5.8.0, 2026-lts-r11 sau mai nou, pe ramura pe care o folosești.
- Actualizează Nginx Plus la 37.0.8.1, 37.3.0.1 sau mai nou, pe ramura pe care o folosești.
- Actualizează Waf la 5.14.4, 5.16.2 sau mai nou, pe ramura pe care o folosești.
Dacă nu poți actualiza imediat
Aplică soluția temporară sau măsura de atenuare din avizul furnizorului până poți actualiza:
Confirmă remedierea
Verifică dacă toate sistemele afectate raportează acum o versiune remediată și revezi avizul furnizorului: remedierile sunt uneori revizuite.
Ți-a fost util?
Cum poate fi exploatată
- Vector de atac
- Rețea
- Complexitatea atacului
- Ridicat
- Condiții de atac
- Niciunul
- Privilegii necesare
- Niciunul
- Interacțiune cu utilizatorul
- Niciunul
- Confidențialitate
- Ridicat
- Integritate
- Ridicat
- Disponibilitate
- Ridicat
Valorile în roșu fac vulnerabilitatea mai ușor de exploatat sau mai gravă. CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Produse afectate
| Produse afectate | Versiuni |
|---|---|
| F5 Dos | ≥ 4.5.0, ≤ 4.7.0 · ≥ 4.8.0, < 4.13.0 |
| F5 Nginx Gateway Fabric | ≥ 1.5.0, ≤ 1.6.2 · ≥ 2.0.0, < 2.9.0 |
| F5 Nginx Ingress Controller | ≥ 5.0.0, < 5.8.0 · ≥ 2026-lts-r1, < 2026-lts-r11 · 3.7.1 · 3.7.2 · 4.0.0 · 4.0.1 |
| F5 Nginx Instance Manager | ≥ 2.19.0, < 2.25.0 |
| F5 Nginx Open Source | ≥ 0.6.18, < 0.8.55 · ≥ 1.0.0, < 1.30.7 · ≥ 1.31.0, < 1.31.9 · ≥ 1.30.0, < 1.30.7 · 0.6.18 |
| F5 Nginx Plus | ≥ 37.0.0, < 37.0.8.1 · ≥ 37.1.0, < 37.3.0.1 · r34 · r35 · r36 · R33 |
| F5 Waf | ≥ 4.12.0, ≤ 4.16.0 · ≥ 5.4.0, ≤ 5.8.0 · ≥ 5.9.0, < 5.14.4 · ≥ 5.16.0, < 5.16.2 |
| Siemens Industrial Edge Cloud Device (IECD) | Nespecificate |
| Siemens Industrial Edge Device Kit - Arm64 | Nespecificate |
| Siemens Industrial Edge Device Kit - X86-64 | Nespecificate |
| Siemens Industrial Edge Hub | Nespecificate |
| Siemens Industrial Edge Management Cloud | Nespecificate |
| Siemens Industrial Edge Management Pro V1 | Nespecificate |
| Siemens Industrial Edge Management Pro V2 | Nespecificate |
| Siemens Industrial Edge Management Virtual | Nespecificate |
| Siemens Industrial Edge Own Device (IEOD) | Nespecificate |
| Siemens Industrial Edge Virtual Device (IEVD) | Nespecificate |
Tip de slăbiciune
- CWE-416 use-after-free
Cronologie
- Publicat:
- Ultima modificare:
Întrebări frecvente
Este CVE-2026-123634 exploatată?
Până acum nu există exploatări confirmate în catalogul CISA KEV. Scorul EPSS estimează o probabilitate de 17.1% de exploatare în următoarele 30 de zile.
Care este scorul CVSS pentru CVE-2026-123634?
CVE-2026-123634 are un scor de bază CVSS 4.0 de 9.2 (critic).
Ce versiuni sunt afectate?
F5 Dos (≥ 4.5.0, ≤ 4.7.0; ≥ 4.8.0, < 4.13.0), F5 Nginx Gateway Fabric (≥ 1.5.0, ≤ 1.6.2; ≥ 2.0.0, < 2.9.0), F5 Nginx Ingress Controller (≥ 5.0.0, < 5.8.0; ≥ 2026-lts-r1, < 2026-lts-r11; 3.7.1; 3.7.2; 4.0.0; 4.0.1), F5 Nginx Instance Manager (≥ 2.19.0, < 2.25.0), F5 Nginx Open Source (≥ 0.6.18, < 0.8.55; ≥ 1.0.0, < 1.30.7; ≥ 1.31.0, < 1.31.9; ≥ 1.30.0, < 1.30.7; 0.6.18), F5 Nginx Plus (≥ 37.0.0, < 37.0.8.1; ≥ 37.1.0, < 37.3.0.1; r34; r35; r36; R33)
Există patch pentru CVE-2026-123634?
Înregistrarea oficială trimite la avize sau patch-uri ale producătorului; vezi „Ce trebuie să faci” mai sus.
Referințe
Date: NVD, CVE.org (cvelistV5), CISA KEV și FIRST EPSS. Rezumat scris de RedCVE cu ajutorul AI, pe baza datelor oficiale.