Skip to content
RedCVE

CVE-2026-81861Schneider Electric SCADAPack 47x insufficiently protected credentials

Schneider ElectricPublished:

CVSS score

5.9

Medium

CVSS 4.0 from se.com

Exploit probability (EPSS)

0.54%

0.54% chance of exploitation in the next 30 days, higher than 46.5% of all CVEs.

CISA KEV

Not in KEV

No confirmed exploitation reported by CISA so far.

Official description

CWE-522: Insufficiently Protected Credentials vulnerability that could result in exposure of authentication information and unauthorized access to RTU functionality.

Source: NVD · CNA: cybersecurity@se.com

How to fix it, step by step

  1. Check whether you're affected

    Find every system running Schneider Electric SCADAPack 47xi, Schneider Electric SCADAPack 47xd, Schneider Electric SCADAPack 470R, Schneider Electric SCADAPack 57x, Schneider Electric SCADAPack 3xx and compare its version with the affected versions.

  2. Watch for an official fix

    No fix or advisory is listed in the official record yet. Follow the vendor's security announcements; this page updates when one is published.

Was this useful?

How it can be exploited

Attack vector
Network
Attack complexity
Low
Attack requirements
Present
Privileges required
None
User interaction
Active
Confidentiality
High
Integrity
None
Availability
None

Values in red make the vulnerability easier to exploit or more damaging. CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

Affected productsVersions
Schneider Electric SCADAPack 47xAll versions
Schneider Electric SCADAPack 47xiAll versions
Schneider Electric SCADAPack 47xdAll versions
Schneider Electric SCADAPack 470RAll versions
Schneider Electric SCADAPack 57xAll versions
Schneider Electric SCADAPack 3xxAll versions
Schneider Electric SCADAPack 32All versions

Weakness

  • CWE-522 insufficiently protected credentials

Timeline

  1. Published:
  2. Last modified:

Frequently asked questions

Is CVE-2026-81861 being exploited?

There is no confirmed exploitation in CISA's KEV catalog so far. Its EPSS score estimates a 0.5% probability of exploitation in the next 30 days.

What is the CVSS score of CVE-2026-81861?

CVE-2026-81861 has a CVSS 4.0 base score of 5.9 (medium).

Which versions are affected?

Schneider Electric SCADAPack 47x (All versions), Schneider Electric SCADAPack 47xi (All versions), Schneider Electric SCADAPack 47xd (All versions), Schneider Electric SCADAPack 470R (All versions), Schneider Electric SCADAPack 57x (All versions), Schneider Electric SCADAPack 3xx (All versions)

Is there a patch for CVE-2026-81861?

No patch is linked in the official record yet. Watch the vendor's security advisories.

References

Data: NVD, CVE.org (cvelistV5), CISA KEV and FIRST EPSS. Summary written by RedCVE with AI assistance from the official data.