CVE-2026-72895Siemens SIMATIC IPC BX-21A vulnerability

SiemensPublished:

CVSS score

8.4

High

CVSS 4.0 from siemens.com

Exploit probability (EPSS)

0.11%

0.11% chance of exploitation in the next 30 days, higher than 1.14% of all CVEs.

CISA KEV

Not in KEV

No confirmed exploitation reported by CISA so far.

Official description

A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device.

Source: NVD · CNA: productcert@siemens.com

How to fix it, step by step

  1. Check whether you're affected

    Find every system running Siemens SIMATIC IPC BX-21A, Siemens SIMATIC IPC RW-543A, Siemens SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G and compare its version with the affected versions.

  2. Watch for an official fix

    No fix or advisory is listed in the official record yet. Follow the vendor's security announcements; this page updates when one is published.

Was this useful?

How it can be exploited

Attack vector
Local
Attack complexity
Low
Attack requirements
None
Privileges required
None
User interaction
Active
Confidentiality
High
Integrity
High
Availability
High

Values in red make the vulnerability easier to exploit or more damaging. CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

Affected productsVersions
Siemens SIMATIC IPC BX-21A< V31.01.13
Siemens SIMATIC IPC RW-543A< V1.1.4
Siemens SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G< V28.01.15

Weakness

Timeline

  1. Published:
  2. Last modified:

Frequently asked questions

Is CVE-2026-72895 being exploited?

There is no confirmed exploitation in CISA's KEV catalog so far. Its EPSS score estimates a 0.1% probability of exploitation in the next 30 days.

What is the CVSS score of CVE-2026-72895?

CVE-2026-72895 has a CVSS 4.0 base score of 8.4 (high).

Which versions are affected?

Siemens SIMATIC IPC BX-21A (< V31.01.13), Siemens SIMATIC IPC RW-543A (< V1.1.4), Siemens SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (< V28.01.15)

Is there a patch for CVE-2026-72895?

No patch is linked in the official record yet. Watch the vendor's security advisories.