Skip to content
RedCVE

CVE-2026-19492IBM Power System S1122 (9824-22a) Firmware use of uninitialized variable

IBMPublished:

CVSS score

3.2

Low

CVSS 3.1 from us.ibm.com

Exploit probability (EPSS)

0.11%

0.11% chance of exploitation in the next 30 days, higher than 1.57% of all CVEs.

CISA KEV

Not in KEV

No confirmed exploitation reported by CISA so far.

Official description

IBM PowerVM Hypervisor FW1120.00 through FW1120.01, FW1110.00 through FW1110.31, and FW1060.00 through FW1060.81 is affected by a vulnerability in a hypervisor call interface. An attacker with root access to a guest partition can read a limited amount of hypervisor memory, potentially exposing sensitive data belonging to the hypervisor or other guest partitions hosted on the same system, resulting in a confidentiality impact. The attacker has no control over which memory contents are returned. This vulnerability is of particular concern in multi-tenant environments where guests may run arbitrary OS images.

Source: NVD · CNA: psirt@us.ibm.com

How to fix it, step by step

  1. Check whether you're affected

    Find every system running IBM Power System S1122 (9824-22a) Firmware, IBM Power System S1124 (9824-42a) Firmware, IBM Power System S1122s (9824-22b) Firmware, IBM Power System S1114 (9824-41b) Firmware, IBM Power System L1122 (9856-22h) Firmware and compare its version with the affected versions.

  2. Apply the vendor's fix

    The official record doesn't name a fixed version. The vendor's advisory describes the fix:

Was this useful?

How it can be exploited

Attack vector
Local
Attack complexity
Low
Privileges required
High
User interaction
None
Scope
Changed
Confidentiality
Low
Integrity
None
Availability
None

Values in red make the vulnerability easier to exploit or more damaging. CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:N

Affected products

Affected productsVersions
IBM Power System S1122 (9824-22a) Firmware≥ fw1110.00, < fw1110.32 · ≥ fw1120.00, < fw1120.02
IBM Power System S1124 (9824-42a) Firmware≥ fw1110.00, < fw1110.32 · ≥ fw1120.00, < fw1120.02
IBM Power System S1122s (9824-22b) Firmware≥ fw1110.00, < fw1110.32 · ≥ fw1120.00, < fw1120.02
IBM Power System S1114 (9824-41b) Firmware≥ fw1110.00, < fw1110.32 · ≥ fw1120.00, < fw1120.02
IBM Power System L1122 (9856-22h) Firmware≥ fw1110.00, < fw1110.32 · ≥ fw1120.00, < fw1120.02
IBM Power System L1124 (9856-42h) Firmware≥ fw1110.00, < fw1110.32 · ≥ fw1120.00, < fw1120.02
IBM Power System E1150 (9043-mru) Firmware≥ fw1110.00, < fw1110.32 · ≥ fw1120.00, < fw1120.02
IBM Power System S1112 (9242-21b) Firmware≥ fw1120.00, < fw1120.02
IBM Power System S1112 (9242-21t) Firmware≥ fw1120.00, < fw1120.02
IBM Power System E1080 (9080-hex) Firmware≥ fw1060.00, < fw1060.82
IBM Power System S1022 (9105-22a) Firmware≥ fw1060.00, < fw1060.82
IBM Power System S1024 (9105-42a) Firmware≥ fw1060.00, < fw1060.82
IBM Power System S1022s (9105-22b) Firmware≥ fw1060.00, < fw1060.82
IBM Power System S1014 (9105-41b) Firmware≥ fw1060.00, < fw1060.82
IBM Power System L1022 (9786-22h) Firmware≥ fw1060.00, < fw1060.82
IBM Power System L1024 (9786-42h) Firmware≥ fw1060.00, < fw1060.82
IBM Power System E1050 (9043-mrx) Firmware≥ fw1060.00, < fw1060.82
IBM Power System S1012 (9028-21b) Firmware≥ fw1060.00, < fw1060.82
IBM Power System E1180 (9080-heu) Firmware≥ fw1110.00, < fw1110.32 · ≥ fw1120.00, < fw1120.02
IBM PowerVM Hypervisor≥ FW1120.00, ≤ FW1120.01 · ≥ FW1110.00, ≤ FW1110.31 · ≥ FW1060.00, ≤ FW1060.81

Weakness

  • CWE-457 use of uninitialized variable

Timeline

  1. Published:
  2. Last modified:

Frequently asked questions

Is CVE-2026-19492 being exploited?

There is no confirmed exploitation in CISA's KEV catalog so far. Its EPSS score estimates a 0.1% probability of exploitation in the next 30 days.

What is the CVSS score of CVE-2026-19492?

CVE-2026-19492 has a CVSS 3.1 base score of 3.2 (low).

Which versions are affected?

IBM Power System S1122 (9824-22a) Firmware (≥ fw1110.00, < fw1110.32; ≥ fw1120.00, < fw1120.02), IBM Power System S1124 (9824-42a) Firmware (≥ fw1110.00, < fw1110.32; ≥ fw1120.00, < fw1120.02), IBM Power System S1122s (9824-22b) Firmware (≥ fw1110.00, < fw1110.32; ≥ fw1120.00, < fw1120.02), IBM Power System S1114 (9824-41b) Firmware (≥ fw1110.00, < fw1110.32; ≥ fw1120.00, < fw1120.02), IBM Power System L1122 (9856-22h) Firmware (≥ fw1110.00, < fw1110.32; ≥ fw1120.00, < fw1120.02), IBM Power System L1124 (9856-42h) Firmware (≥ fw1110.00, < fw1110.32; ≥ fw1120.00, < fw1120.02)

Is there a patch for CVE-2026-19492?

The official record links to vendor advisories or patches; see “What to do” above.

References

Data: NVD, CVE.org (cvelistV5), CISA KEV and FIRST EPSS. Summary written by RedCVE with AI assistance from the official data.