Skip to content
RedCVE

CVE-2026-116570Freeswitch stack-based buffer overflow

freeswitchSignalWirePublished:

CVSS score

7.5

High

CVSS 3.1 from github.com

Exploit probability (EPSS)

0.55%

0.55% chance of exploitation in the next 30 days, higher than 47.1% of all CVEs.

CISA KEV

Not in KEV

No confirmed exploitation reported by CISA so far.

Official description

FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.2, http_directory_auth() rebuilt an expected user@domain:password credential and base64-encoded it into an 80-byte buffer using an encoder without an output-length argument. A configured credential longer than 57 characters overflowed the stack before the supplied HTTP Basic password was compared. An unauthenticated client only needed to name an existing directory user on an exposed mod_xml_rpc HTTP listener; the module is built but not loaded by the stock configuration. The overflow can corrupt the stack and crash FreeSWITCH, ending every active call, although the overrun bytes come from the configured credential and remote code execution has not been demonstrated. This issue is fixed in version 1.11.2.

Source: NVD · CNA: security-advisories@github.com

How to fix it, step by step

  1. Check whether you're affected

    Find every system running Freeswitch and compare its version with the affected versions.

  2. Update to a fixed version

    • Update Freeswitch to 1.11.2 or later.
  3. If you can't update right away

  4. Confirm the fix

    Check that every affected system now reports a fixed version, and recheck the vendor's advisory: fixes are sometimes revised.

Was this useful?

How it can be exploited

Attack vector
Network
Attack complexity
Low
Privileges required
None
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Values in red make the vulnerability easier to exploit or more damaging. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Affected products

Affected productsVersions
freeswitch Freeswitch< 1.11.2
SignalWire Freeswitch< 1.11.2

Weakness

Timeline

  1. Published:
  2. Last modified:

Frequently asked questions

Is CVE-2026-116570 being exploited?

There is no confirmed exploitation in CISA's KEV catalog so far. Its EPSS score estimates a 0.6% probability of exploitation in the next 30 days.

What is the CVSS score of CVE-2026-116570?

CVE-2026-116570 has a CVSS 3.1 base score of 7.5 (high).

Which versions are affected?

Freeswitch Freeswitch (< 1.11.2), Signalwire Freeswitch (< 1.11.2)

Is there a patch for CVE-2026-116570?

The official record links to vendor advisories or patches; see “What to do” above.

References

Data: NVD, CVE.org (cvelistV5), CISA KEV and FIRST EPSS. Summary written by RedCVE with AI assistance from the official data.