CVE-2026-112136Siemens Mendix Studio Pro 11 vulnerability
CVSS score
9.2
Critical
CVSS 4.0 from siemens.com
Exploit probability (EPSS)
0.30%
0.30% chance of exploitation in the next 30 days, higher than 23.5% of all CVEs.
CISA KEV
Not in KEV
No confirmed exploitation reported by CISA so far.
Official description
A vulnerability has been identified in Mendix Studio Pro 11 (All versions >= V11.15.0 < V11.16.0), Mendix Studio Pro 11.12 (All versions >= V11.12.6 < V11.12.7). The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely.
Source: NVD · CNA: productcert@siemens.com
How to fix it, step by step
Check whether you're affected
Find every system running Siemens Mendix Studio Pro 11.12 and compare its version with the affected versions.
Watch for an official fix
No fix or advisory is listed in the official record yet. Follow the vendor's security announcements; this page updates when one is published.
Was this useful?
How it can be exploited
- Attack vector
- Network
- Attack complexity
- Low
- Attack requirements
- Present
- Privileges required
- None
- User interaction
- None
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Values in red make the vulnerability easier to exploit or more damaging. CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Affected products
| Affected products | Versions |
|---|---|
| Siemens Mendix Studio Pro 11 | ≥ V11.15.0, < V11.16.0 |
| Siemens Mendix Studio Pro 11.12 | ≥ V11.12.6, < V11.12.7 |
Weakness
Timeline
- Published:
- Last modified:
Frequently asked questions
Is CVE-2026-112136 being exploited?
There is no confirmed exploitation in CISA's KEV catalog so far. Its EPSS score estimates a 0.3% probability of exploitation in the next 30 days.
What is the CVSS score of CVE-2026-112136?
CVE-2026-112136 has a CVSS 4.0 base score of 9.2 (critical).
Which versions are affected?
Siemens Mendix Studio Pro 11 (≥ V11.15.0, < V11.16.0), Siemens Mendix Studio Pro 11.12 (≥ V11.12.6, < V11.12.7)
Is there a patch for CVE-2026-112136?
No patch is linked in the official record yet. Watch the vendor's security advisories.
References
Data: NVD, CVE.org (cvelistV5), CISA KEV and FIRST EPSS. Summary written by RedCVE with AI assistance from the official data.