CVE-2026-111215Pfsense OS command injection
CVSS score
8.6
High
CVSS 4.0 from vulncheck.com
Exploit probability (EPSS)
7.51%
7.51% chance of exploitation in the next 30 days, higher than 94.6% of all CVEs.
CISA KEV
Not in KEV
No confirmed exploitation reported by CISA so far.
Official description
Netgate pfSense CE through 2.9.0 and Plus through 26.07 contains an OS command injection vulnerability that allows authenticated users to execute commands as root by supplying a crafted wireless parent interface name. Attackers with limited Wireless Edit or Interface Assignments privileges can submit values like ath0;<cmd> via interfaces_wireless_edit.php or interfaces_assign.php, which interface_wireless_clone() interpolates unescaped into an ifconfig shell command.
Source: NVD · CNA: disclosure@vulncheck.com
How to fix it, step by step
Check whether you're affected
Find every system running Netgate PfSense CE, Netgate PfSense Plus and compare its version with the affected versions.
Update to a fixed version
- Update PfSense CE to 2.9.1 or later.
- Update PfSense Plus to 26.07.1 or later.
Confirm the fix
Check that every affected system now reports a fixed version, and recheck the vendor's advisory: fixes are sometimes revised.
Was this useful?
How it can be exploited
- Attack vector
- Network
- Attack complexity
- Low
- Attack requirements
- None
- Privileges required
- High
- User interaction
- None
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Values in red make the vulnerability easier to exploit or more damaging. CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Affected products
| Affected products | Versions |
|---|---|
| pfsense Pfsense | ≤ 2.9.0 |
| Netgate PfSense CE | < 2.9.1 |
| Netgate PfSense Plus | < 26.07.1 |
Weakness
- CWE-78 OS command injection
Timeline
- Published:
- Last modified:
Frequently asked questions
Is CVE-2026-111215 being exploited?
There is no confirmed exploitation in CISA's KEV catalog so far. Its EPSS score estimates a 7.5% probability of exploitation in the next 30 days.
What is the CVSS score of CVE-2026-111215?
CVE-2026-111215 has a CVSS 4.0 base score of 8.6 (high).
Which versions are affected?
Pfsense Pfsense (≤ 2.9.0), Netgate PfSense CE (< 2.9.1), Netgate PfSense Plus (< 26.07.1)
Is there a patch for CVE-2026-111215?
The official record links to vendor advisories or patches; see “What to do” above.
References
- abraxaslabs.tech/research/pfsense-ce-leftovers(Issue Tracking)
- docs.netgate.com/downloads/pfSense-SA-26_31.webgui.asc
- docs.netgate.com/pfsense/en/latest/releases/26-07-1_2-9-1.html
- github.com/abraxas/pfsense-assign-if-add(Issue Tracking)
- github.com/abraxas/pfsense-wireless-clone(Issue Tracking)
- github.com/pfsense/pfsense/blob/9363ac5b8651a1c7a333180425ce7719070f95f9/src/etc/inc/interfaces.inc#L3370(Product)
- github.com/pfsense/pfsense/blob/9363ac5b8651a1c7a333180425ce7719070f95f9/src/usr/local/www/interfaces_assign.php#L187(Product)
- github.com/pfsense/pfsense/blob/9363ac5b8651a1c7a333180425ce7719070f95f9/src/usr/local/www/interfaces_wireless_edit.php#L77(Product)
- redmine.pfsense.org/issues/17205
- www.vulncheck.com/advisories/netgate-pfsense-ce-through-2.9.0-os-command-injection-via-wireless-parent-interface(Third Party Advisory)
Data: NVD, CVE.org (cvelistV5), CISA KEV and FIRST EPSS. Summary written by RedCVE with AI assistance from the official data.