Skip to content
RedCVE

CVE-2026-100618Cap GO Capgo.app authorization bypass through user-controlled key (IDOR)

Cap-goPublished:

CVSS score

8.7

High

CVSS 4.0 from vulncheck.com

Exploit probability (EPSS)

0.26%

0.26% chance of exploitation in the next 30 days, higher than 17.6% of all CVEs.

CISA KEV

Not in KEV

No confirmed exploitation reported by CISA so far.

Official description

Capgo (capgo.app) is affected by an authorization flaw in the app icon update path. The PUT /app/:id endpoint accepts a user-controlled `icon` value, normalizes it, and stores it in public.apps.icon_url without verifying that the image path belongs to the target app's own image namespace (e.g. org/{owner_org}/{app_id}/...). Updating apps.icon_url fires the on_app_update trigger, whose worker reads record.icon_url and calls cleanStoredImageMetadata(), which runs with service-role credentials (supabaseAdmin()) and downloads and re-uploads the referenced storage object with upsert: true. As a result, an authenticated holder of an app-limited write API key can cause the privileged worker to rewrite an out-of-scope private image object (for example an organization logo) that the key cannot read or write directly under Supabase Storage RLS. All versions are affected; no patched version was available at the time of the advisory.

Source: NVD · CNA: disclosure@vulncheck.com

How to fix it, step by step

  1. Check whether you're affected

    Find every system running Cap-go Capgo.app and compare its version with the affected versions.

  2. Watch for an official fix

    No fix or advisory is listed in the official record yet. Follow the vendor's security announcements; this page updates when one is published.

Was this useful?

How it can be exploited

Attack vector
Network
Attack complexity
Low
Attack requirements
None
Privileges required
None
User interaction
None
Confidentiality
High
Integrity
None
Availability
None

Values in red make the vulnerability easier to exploit or more damaging. CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

Affected productsVersions
Cap-go Capgo.appNot specified

Weakness

  • CWE-639 authorization bypass through user-controlled key (IDOR)

Timeline

  1. Published:
  2. Last modified:

Frequently asked questions

Is CVE-2026-100618 being exploited?

There is no confirmed exploitation in CISA's KEV catalog so far. Its EPSS score estimates a 0.3% probability of exploitation in the next 30 days.

What is the CVSS score of CVE-2026-100618?

CVE-2026-100618 has a CVSS 4.0 base score of 8.7 (high).

Which versions are affected?

Cap GO Capgo.app

Is there a patch for CVE-2026-100618?

No patch is linked in the official record yet. Watch the vendor's security advisories.

References

Data: NVD, CVE.org (cvelistV5), CISA KEV and FIRST EPSS. Summary written by RedCVE with AI assistance from the official data.