Skip to content
RedCVE

CVE-2024-8957PTZOptics PT30X camera OS command injection

ExploitedPTZOpticsPublished:

CVSS score

7.2

High

CVSS 3.1 from NVD

Exploit probability (EPSS)

79.8%

79.8% chance of exploitation in the next 30 days, higher than 99.6% of all CVEs.

CISA KEV

Actively exploited

Added to KEV on 4 Nov 2024.

US federal deadline to fix: 25 Nov 2024.

In plain words

A remote attacker without a login can run operating system commands on PTZOptics PT30X-SDI and PT30X-NDI cameras when chained with CVE-2024-8956. The camera does not properly check the NTP server address setting, which lets crafted input reach the system shell. Firmware before 6.3.40 is affected, and CISA reports active exploitation, so restrict network access to these cameras and discontinue use if mitigations are unavailable.

Official description

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.

Source: NVD · CNA: disclosure@vulncheck.com

How to fix it, step by step

  1. Treat it as urgent

    Attackers are already exploiting this flaw: CISA added it to its Known Exploited Vulnerabilities list on 4 Nov 2024.

    US federal agencies must fix it by 25 Nov 2024. It's a sensible deadline for everyone else too.

    CISA's full instruction
    Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
  2. Check whether you're affected

    Find every system running PTZOptics Pt30x-sdi Firmware, PTZOptics Pt30x-ndi-xx-g2 Firmware, PTZOptics Pt30x-ndi Firmware and compare its version with the affected versions.

  3. Update to a fixed version

    • Update Pt30x-sdi Firmware, Pt30x-ndi-xx-g2 Firmware, Pt30x-ndi Firmware to 6.3.40 or later.
  4. Check for signs of compromise

    Updating closes the flaw but doesn't remove an attacker who got in earlier. Review affected systems for unknown accounts, unusual logins and configuration changes, and use any indicators of compromise the vendor or CISA publish.

  5. Confirm the fix

    Check that every affected system now reports a fixed version, and recheck the vendor's advisory: fixes are sometimes revised.

Was this useful?

How it can be exploited

Attack vector
Network
Attack complexity
Low
Privileges required
High
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Values in red make the vulnerability easier to exploit or more damaging. CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Affected products

Affected productsVersions
PTZOptics Pt30x-sdi Firmware< 6.3.40
PTZOptics Pt30x-ndi-xx-g2 Firmware< 6.3.40
PTZOptics PT30X-SDI< 6.3.40
PTZOptics PT30X-NDI< 6.3.40
PTZOptics Pt30x-ndi Firmware< 6.3.40

Weakness

Timeline

  1. Published:
  2. Added to CISA KEV:
  3. Last modified:

Frequently asked questions

Is CVE-2024-8957 being exploited?

Yes. CISA added CVE-2024-8957 to its Known Exploited Vulnerabilities catalog on 4 Nov 2024, which means there is evidence of exploitation in the wild. Its EPSS score estimates a 79.8% probability of exploitation in the next 30 days.

What is the CVSS score of CVE-2024-8957?

CVE-2024-8957 has a CVSS 3.1 base score of 7.2 (high).

Which versions are affected?

Ptzoptics Pt30x-sdi Firmware (< 6.3.40), Ptzoptics Pt30x-ndi-xx-g2 Firmware (< 6.3.40), Ptzoptics PT30X-SDI (< 6.3.40), Ptzoptics PT30X-NDI (< 6.3.40), Ptzoptics Pt30x-ndi Firmware (< 6.3.40)

Is there a patch for CVE-2024-8957?

The official record links to vendor advisories or patches; see “What to do” above.

References

Data: NVD, CVE.org (cvelistV5), CISA KEV and FIRST EPSS. Summary written by RedCVE with AI assistance from the official data.