Skip to content
RedCVE

CVE-2024-39717Versa Director unrestricted file upload via favicon option

Exploitedversa-networksVersaPublished:

CVSS score

7.2

High

CVSS 3.1 from NVD

Exploit probability (EPSS)

3.99%

3.99% chance of exploitation in the next 30 days, higher than 90.8% of all CVEs.

CISA KEV

Actively exploited

Added to KEV on 23 Aug 2024.

US federal deadline to fix: 13 Sept 2024.

In plain words

An attacker who already holds a provider admin login on Versa Director can upload a malicious file disguised as a .png image through the favicon setting. Tenant-level users cannot use this option, and the affected versions are 21.2.2, 21.2.3 and 22.1.1. CISA reports active exploitation, so apply Versa's fix or mitigations as soon as possible.

Official description

The Versa Director GUI provides an option to customize the look and feel of the user interface. This option is only available for a user logged with Provider-Data-Center-Admin or Provider-Data-Center-System-Admin. (Tenant level users do not have this privilege). The “Change Favicon” (Favorite Icon) option can be mis-used to upload a malicious file ending with .png extension to masquerade as image file. This is possible only after a user with Provider-Data-Center-Admin or Provider-Data-Center-System-Admin has successfully authenticated and logged in.

Source: NVD · CNA: support@hackerone.com

How to fix it, step by step

  1. Treat it as urgent

    Attackers are already exploiting this flaw: CISA added it to its Known Exploited Vulnerabilities list on 23 Aug 2024.

    US federal agencies must fix it by 13 Sept 2024. It's a sensible deadline for everyone else too.

    CISA's full instruction
    Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
  2. Check whether you're affected

    Find every system running versa-networks Versa Director, Versa Director and compare its version with the affected versions.

  3. Update to a fixed version

    • Update Versa Director to 21.2.3_2024-06-21 or later.
  4. If you can't update right away

  5. Check for signs of compromise

    Updating closes the flaw but doesn't remove an attacker who got in earlier. Review affected systems for unknown accounts, unusual logins and configuration changes, and use any indicators of compromise the vendor or CISA publish.

  6. Confirm the fix

    Check that every affected system now reports a fixed version, and recheck the vendor's advisory: fixes are sometimes revised.

Was this useful?

How it can be exploited

Attack vector
Network
Attack complexity
Low
Privileges required
High
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Values in red make the vulnerability easier to exploit or more damaging. CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Affected products

Affected productsVersions
versa-networks Versa Director21.2.2 · 21.2.3 · 22.1.1 · 22.1.2 · 22.1.3 · ≥ 21.2.3, < 21.2.3_2024-06-21
Versa Director≥ 21.2.2, ≤ 21.2.2 · ≥ 21.2.3 before 2024-06-21, < 21.2.3 before 2024-06-21 · ≥ 22.1.1, ≤ 22.1.1 · ≥ 22.1.2 before 2024-06-21, ≤ 22.1.2 before 2024-06-21 · ≥ 22.1.3 before 2024-06-21, ≤ 22.1.3 before 2024-06-21

Weakness

Timeline

  1. Published:
  2. Added to CISA KEV:
  3. Last modified:

Frequently asked questions

Is CVE-2024-39717 being exploited?

Yes. CISA added CVE-2024-39717 to its Known Exploited Vulnerabilities catalog on 23 Aug 2024, which means there is evidence of exploitation in the wild. Its EPSS score estimates a 4.0% probability of exploitation in the next 30 days.

What is the CVSS score of CVE-2024-39717?

CVE-2024-39717 has a CVSS 3.1 base score of 7.2 (high).

Which versions are affected?

Versa Networks Versa Director (21.2.2; 21.2.3; 22.1.1; 22.1.2; 22.1.3; ≥ 21.2.3, < 21.2.3_2024-06-21), Versa Director (≥ 21.2.2, ≤ 21.2.2; ≥ 21.2.3 before 2024-06-21, < 21.2.3 before 2024-06-21; ≥ 22.1.1, ≤ 22.1.1; ≥ 22.1.2 before 2024-06-21, ≤ 22.1.2 before 2024-06-21; ≥ 22.1.3 before 2024-06-21, ≤ 22.1.3 before 2024-06-21)

Is there a patch for CVE-2024-39717?

The official record links to vendor advisories or patches; see “What to do” above.

References